HOME > PRODUCT > Phase-Angle控制 |
|
|
Phase Angle 控制
|
TPP2-025:160
|
|
|
|
Blown fuse, SCR short and load out detection
| Overcurrent protection and alarm output
| Protection against inrush currents
| SOFT START(0.3~30sec DEFAULT : 10sec)
| SOFT UP/DOWN(0.3~30sec DEFAULT : 10sec)
| Sink overheat protection
| Maximum output adjustment
| 50/60Hz Combined
| According to load variation protection circuit design for system control and stability
| Current, voltage and power feedback
| Communication functions
|
|
|
|
|
|
|
|
구 분 |
사 양 |
POWER |
220V(Tolerance -30% ~ +10%) |
Rated frequency |
50/60Hz Combined |
Rated Current |
25, 40, 55, 70, 90, 110, 130, 160A |
Input signal (Auto) |
4 ~20mA, 0 ~ 20mA, 0 ~ 5V, 1 ~ 5V, 0 ~ 10V |
Input Signal (Manual) |
External resistance 10㏀ |
Output Range |
95% |
Applied load |
Resistance / Fluidity |
Alarm Capacity |
Basic 2 POINTS(NORMAL OPEN, NORMAL CLOSE) |
Alarm Type |
Blown fuse, overcurrent, overtemperature heat sink temperature, load short circuit, SCR paragraph |
Cooling System |
Forced air cooling |
Operating temperature |
Operating temperature |
Warranty operation temperature |
-10 ~ 85℃ |
45℃ |
SOFT START |
0.3 ~ 30sec.(Possible changes) |
SOFT UP/DOWN |
No function |
Insulation resistance |
Between power terminal and CASE 200 ㏁ (500V DC) |
FEEDBACK Function |
Current, voltage, power can be mounted FEEDBACK (OPTION) |
Communication methods |
Option(RS-485 PC-Link, MODBUS(ASCII), SYNC MAX : 19200bps) | |
|
|
|
|
|
|
|
|